Module M10: In-Silico PCR Coverage Analysis
Module M10 is the validation checkpoint of the pipeline. It evaluates the diagnostic sensitivity (coverage) of the final candidate assays by simulating amplification against a large database of genomic sequences.Amplification Emulation (SeqKit)
The pipeline utilizes SeqKit (seqkit amplicon) to simulate physical PCR/RAA amplification across thousands of sequences:
Custom Binding Kinetics & Mismatch Scoring
A simple mismatch count is not sufficient for evaluating assay performance. Our custom script (scripts/m10_insilico_pcr.py) parses the alignment and applies strict molecular kinetics filters:
1. 3’ Anchoring Penalty (Recombinase Extension Region)
For RAA and RPA isothermal assays, the recombinase enzyme binds to the primer and initiates strand displacement. Mismatches near the 3’ end prevent efficient polymerase extension.- Critical Region (
raa_3prime_bp): The last 4 bp of the 3’ end of either primer. - Tolerance (
raa_max_3prime_mm): Maximum 1 mismatch allowed in this region. Exceeding this triggers a hard rejection.
2. Internal Mismatch Tolerance
- RAA/RPA: Up to 4 mismatches are tolerated in the internal region (primer length minus
raa_3prime_bp), reflecting the long primer length (30–35 bp) which accommodates higher mismatch loads. This is conservative relative to the TwistAmp manual §2.7, which reports RPA performance unaffected by 5–9 mismatches across primers and probe. - PCR: Up to 2 mismatches are tolerated in the 5’ half; mismatches in the 3’ critical end must be zero.
3. Probe Cleavage — What Is and Is Not Checked
Fluorogenic RAA probes carry an internal abasic residue (tetrahydrofuran, THF) between a dT-fluorophore and a dT-quencher. The signal only appears when the repair enzyme in the kit — Exonuclease III forexo probes, Endonuclease IV for nfo/fpg probes — cleaves that residue, separating the two dyes. Both enzyme systems share the same probe geometry; the choice affects how the signal is read (real-time fluorescence vs lateral flow), not where the abasic residue goes.
!!! warning “Corrected: there is no 2 bp cleavage window”
Earlier revisions of this page stated that “mismatches within 2 bp of the THF site are prohibited… leading to false-negatives even if amplification succeeds”. That rule has no support and has been removed. No literature or vendor documentation was found for it, and the primary source contradicts it:
- TwistAmp Assay Design Manual §2.7: “RPA is generally quite robust to mismatches. It has been shown that the performance of RPA assays is not affected when primers and probe carry 5–9 base pair mismatches”.
- §3.1.1 sanctions a deliberate mismatch inside that very window: “It is also possible to tolerate a mismatch in the probe such that if two conveniently separated thymines cannot be located one can simply ignore the mismatch of one of the thymines”. Those thymines are the dT-label positions, which §3.1.2 places 0, 1 or 2 bases from the THF.
probe_label_mismatches so they can be discounted rather than counted as target variation.
What M10 checks instead
A probe is judged on its total mismatch load against each surveillance sequence —raa_probe_max_mm, default 5, the conservative end of the 5–9 range the manual describes as tolerated. Probe geometry itself (≥30 bases 5’ of the abasic residue, ≥15 bases 3’, dT-flanked labels) is enforced upstream at design time in PrimerLab and is not re-derived here.
!!! warning “Corrected: a probe was being judged as if it were a primer”
Until this revision, M10 ran the probe through the same assess_raa_binding() routine as the primers, with raa_3prime_bp=8 and raa_max_3prime_mm=1. That applies primer extension kinetics to an oligo that is chemically prevented from being extended: an RAA probe carries a 3’ blocking group (C3-spacer, phosphate or biotin-TEG) precisely so the polymerase cannot extend it, so a mismatch at its 3’ terminus has none of the consequence that makes 3’ mismatches decisive for a primer.
The effect was a false rejection. Measured on a 46 nt probe:
Only probes with more than one mismatch clustered near the 3’ end change verdict — but those were being counted as detection failures, so reported RAA coverage was understated for exactly the sequences carrying 3’-proximal probe variation.
How to Read the Output Reports
Module M10 produces three validation reports underresults/{BUILD}/m10/{mode}/:
1. coverage_summary.tsv
This file records the raw coverage percentages broken down by subtype, collection year, and country.
2. coverage_report.md
A human-readable markdown report that summarizes overall performance, highlights any sudden drops in coverage, and lists the accessions of sequences that failed validation.
3. coverage_heatmap.html
An interactive HTML dashboard containing a Plotly heatmap.
How to interpret the Heatmap:
- The X-axis displays the collection years.
- The Y-axis displays the viral subtypes.
- The colour scale ranges from Red (0% coverage) to Green (100% coverage).
- Hovering over a cell shows the exact sample count (
amplified / total_sequences) and coverage percentage. - Actionable Insight: A sudden shift from green to red in recent years indicates antigenic/diagnostic drift. The primer set is losing specificity to emerging strains and needs to be replaced.
- Filter Rare Subtypes: Subtypes with fewer than
insilico_pcr.min_subtype_seqs(default 30) sequences are collapsed into the"Other (rare, n < 30)"row to prevent statistically insignificant coverage fluctuations from skewing the heatmap.